View our schedule in a real-time and

Schedule your appointment online

(727) 275-7555

Call us for same day professional service!

Thermador Oven Broil Not Working: Spark Module and Control Board Replacement

Model PGR364GLP • Gas range • St. Petersburg, FL

Problem
Thermador oven broil not working; Bake cycling and door lock acting strangely
Cause
Failed broil ignition module and malfunctioning main control board
Repair
Broil spark module 00418880 and main power control board 00709785 replaced
Result
Fixed on second visit
Replacement control board beside its installation instructions.

Replacement control board beside its installation instructions.

Diagnosis and repair

Two oven problems at the same time

The customer called about a Thermador oven broil not working. Selecting Broil did not light the burner at all. Bake had a different set of symptoms: the gas flame stayed on for about 20 seconds, went out for roughly five seconds, then repeated the cycle. At the same time, the needle on the oven’s electronic temperature gauge shook instead of giving a steady reading, and the door lock moved partway toward the locked position even though the oven was not in Self Clean.

Why Broil would not ignite

This Thermador range uses separate high-voltage ignition modules for the oven burners, with the main control board coordinating their operation. The technician traced the Broil problem to a failed ignition module that was no longer producing the spark needed to light the burner. A working gas burner cannot ignite without its required ignition spark, so the broil module needed replacement.

The strange Bake symptoms pointed to the main control

The Bake problem was different. The door lock should operate during the self-clean cycle, not when Bake is selected. The oven also had an electronic temperature indicator styled like an old-fashioned dial, so the trembling needle was another sign that the controls were not behaving normally. Along with the repeated short burner cycles, these symptoms pointed to a malfunctioning main control board.

Two parts, two different installation jobs

Once the customer approved the repair, we obtained a replacement broil ignition module, part 00418880, and main power control board, part 00709785. The ignition module was a straightforward replacement. The main board required more careful setup because the replacement was designed for several versions of the range. The technician followed its installation instructions and set the board’s jumper configuration for this model before completing the wiring connections.

Broil lights, and Bake behaves normally again

On the return visit, the Broil burners ignited during testing; the two sections came on one after the other. The electronic temperature gauge responded normally, the door lock stopped trying to engage during Bake, and the Bake burner operated properly. Replacing the failed broil ignition module and main control board resolved both oven complaints.